Commit Graph

442 Commits (3b40ec7918531cf60d9d4b7749d97ea3f0bf1b1f)
 

Author SHA1 Message Date
Alejandro Sirgo Rica 3b40ec7918 sw_inventory: consolidate os_probe logic
Reuse os_probe() function from probe.py and change the fallback
case to "unknown" to prevent OS id mismatch in ogserver.

The OS id mismatch causes the images to stop being associated with
partitions after the /refresh command.
2024-09-25 14:35:41 +02:00
Alejandro Sirgo Rica 51258613cc src: verify the fields of the efibootmgr json in /refresh
Don't send the efi data in the /refresh payload if efibootmgr
is missing any of the json keys.

Log the missing keys in case of missing some.
2024-09-25 14:35:41 +02:00
Alejandro Sirgo Rica 11a963c709 utils: Add windows_register_c_drive implementation
Add python implementation of the legacy ogWindowsRegisterPartition
function.

This function configures the system partition to be considered the
new C drive after a Windows image restore.

The drive letter configuration is stored in the SYSTEM hive of
the windows registry. The node MountedDevices contains all the
configuration as key-value pairs.
The C drive key \DosDevices\C: contains a different value based on
the partitioning type.

GPT
the value is DMIO:ID: followed by the 16 byte GUID of the
partition.
Example: DMIO:ID:\xc9\xfc\x1c\x86\x13\x11O\t\xa2\x9c{/\xf1\xdf\xe4)

MBR
The value is a little endian byte sequence with 2 parts.
The first 4 bytes correspond to the disk id. The second part is
the byte offset start of the partition in that disk.
Example: \xe1\\\x9cP\x00\x00\x10j\x18\x00\x00\x00

If we format the MBR value in a more readable way we get
e1 5c 9c 50 00 00 10 6a 18 00 00 00
In this case the disk ID is 509c5ce1.
The partition offset is 186a100000.

This patch adds the following helper functions to:

- get_disk_id_bytes(): to obtain the disk identifier.

- get_part_id_bytes(): to obtain a partition identifier as UUID
  for MBR or DMIO:ID format for GPT.

- get_sector_size(): to query the sector size of a specific disk.
  Read /sys/class/block/{device_name}/queue/hw_sector_size to obtain the value.
  This is MBR specific.

- get_partition_start_offset(): to query the start sector of a specific
  partition and disk. Use sfdisk with the -J argument to get fdisk data in
  json format. This is MBR specific.
2024-09-12 10:43:09 +02:00
Alejandro Sirgo Rica 595770163a live: add boot entries into /refresh payload
Add 'efi' key into the refresh payload. The value for that key
has the following structure:

'efi': {
  'entries': [
    {
      "order": 0,
      "name": "Boot0000",
      "active": false,
      "description": "grub"
    },
    {
      "order": 1,
      "name": "Boot0001",
      "active": true,
      "description": "UEFI: PXE IP4 Realtek PCIe GBE Family Controller"
    }
  ]
}

If the client is not a EFI system it won't add the 'efi' field.
If an entry is not in the boot order it won't have the 'order' field.
2024-09-10 17:23:18 +02:00
Alejandro Sirgo Rica f31e55fea4 bcd: make recovery modifications optional
Ignore recovery disable if no Recovery node is found in the BCD.
2024-09-10 15:37:08 +02:00
OpenGnSys Support Team 084650e4b1 live: use correct variable name in restore unicast cache
fe40f9c5 ('src: add POST cache/fetch method') broke unicast cache restore.

(2024-09-09 10:05:22) ogClient: [ERROR] - name 'image_name' is not defined
Traceback (most recent call last):
File "/opt/opengnsys/ogClient/src/ogRest.py", line 175, in image_restore
payload = ogRest.operations.image_restore(request, ogRest)
File "/opt/opengnsys/ogClient/src/live/ogOperations.py", line 520, in image_restore
self._restore_image_unicast(repo, name, partdev, cache)
File "/opt/opengnsys/ogClient/src/live/ogOperations.py", line 242, in _restore_image_unicast
image_path = f'{OG_CACHE_IMAGE_PATH}{image_name}.img'
NameError: name 'image_name' is not defined
2024-09-09 12:23:00 +02:00
OpenGnSys Support Team 05b7a576b0 live: incorrect indentation
f2a2f53074 ('live: remove file from cache with no checksum file') broke
indentation which breaks ogClient.
2024-09-03 19:44:43 +02:00
Alejandro Sirgo Rica 6704abc620 live: add disk index bounds check
Add disk index bounds checks for setup() and image_create().
Prevent backtrace logging when an invalid disk index is used.
2024-09-02 14:25:54 +02:00
OpenGnSys Support Team f2a2f53074 live: remove file from cache with no checksum file
Maybe result of a partial download? then, remove it to leave cache in consistent
state.
2024-09-02 13:59:36 +02:00
Alejandro Sirgo Rica f7b37ba010 utils: replace the legacy function ogConfigureFstab
Implement configure_fstab() as a replacement of ogConfigureFstab.

Create src/utils/fstab.py to implement the main fstab
configuration functions. Define two fstab helper classes,
FstabBuilder and FstabEntry.

FstabEntry
Represents each line in the fstab file.
Has the values: device, mountpoint, fstype, options, dump_code
and pass_code.

FstabBuilder
Contains a list of FstabEntry. Handles loading of a
preexisting fstab file and the serialization of multiple
FstabEntry into a file.

The fstab configuration has 3 main steps:

Root partition:
- Update the device field with the device where
the new system is installed.

Swap partition:
- Preserve all the swapfile entries in every case.
- If the filesystem has a swap partition: update the device field
  in the first fstab swap entry and remove the rest swap entries
  pointing to a swap partition. Only one swap partition is supported.
  Create a new fstab entry if no preexisting swap entry exists.
- If the system has no swap partition remove every swap partition
  entry.

EFI partition:
- Update the device field of the EFI fstab entry if it exists.
  Create a new fstab entry if no preexisting EFI entry exists.

Add get_filesystem_id to disk.py to obtain the UUID.
Define every device field as a UUID. That method is more robust
than a plain device path as it works after disks being added or
removed.
2024-08-30 12:19:48 +02:00
OpenGnSys Support Team c09c064f28 postinstall: ignore legacy scripts non-zero return code
legacy scripts are not reliable, legacy scripts continue processing on errors,
warn on errors until they are converted to native code instead.
2024-08-30 11:56:41 +02:00
OpenGnSys Support Team 9270a6c58f src: append .img to log that report image fetching 2024-08-29 13:10:50 +02:00
OpenGnSys Support Team 3d47b5069a src: use logging.warning()
logging.warn() is deprecated since 3.3.

And use .error() instead when command is unsupported or client is busy, that
should not ever happen.
2024-08-27 12:44:13 +02:00
OpenGnSys Support Team 4b62b80be7 utils: bcd: update logging related to BCD updates with MBR partition
MBR requires manual bcdedit invocation to generalize image before creation.
Report via logging that no BCD update occurs.
2024-08-27 12:34:58 +02:00
OpenGnSys Support Team 8839950758 live: report that up-to-date image already exists in cache 2024-08-21 09:28:01 +02:00
OpenGnSys Support Team 19e8825805 utils: return False instead of rising exception
if image file and checksum are not found in the cache, then report checksum
validation has failed so it can proceed to fetch new files from server.
2024-08-21 09:21:53 +02:00
OpenGnSys Support Team 1ca3992f71 src: remove call to restoreImageCustom script
remove call to custom version of legacy script, display warning.
2024-08-21 09:21:53 +02:00
Alejandro Sirgo Rica 9fa4a5f651 live: clean files after a failed cache image copy
Remove image files after a failed image copy operation.
2024-08-09 11:05:02 +02:00
Alejandro Sirgo Rica 73ecb48113 src: log without backtrace in not implemented functions
Don't log a backtrace when a not implemented function is called
in ogClient.
Log a "Function not implemented" message.
2024-08-09 11:05:02 +02:00
Alejandro Sirgo Rica 71b3211d3d postinstall: remove shell=True
Remove the use of shell=True.
2024-08-09 11:05:02 +02:00
Alejandro Sirgo Rica fe40f9c5d6 src: add POST cache/fetch method
Add API REST method to fetch an image.
Consolidate image fetch loging for cache/fetch and image/restore.

Resquest payload structure:
{
    'image': 'linux.img'
    'type': 'TIPTORRENT'
    'repository': '12.141.10.2'
}

The client will try to fetch'image' from 'repository' into cache.

Resquest response structure:
{
    'cache': [
        {'name': 'windows.img', 'size': 2432370213, checksum: '5d4dcc677bc19f40a647d0002f4ade90'},
        {'name': 'linux.img', 'size': 243234534213, checksum: '3eb22f888f88a55ad954f55644e1192e'}
    ]
}
2024-08-09 11:04:56 +02:00
OpenGnSys Support Team 89d711be2a postinstall: ignore output when invoking legacy scripts
output is never consumed.
2024-08-08 13:36:32 +02:00
OpenGnSys Support Team 9be639ae78 postinstall: add logging to report this stage
log that image restoration has entered OS configuration stage.
2024-08-08 12:21:05 +02:00
OpenGnSys Support Team 9ee5f4adaa live: move filesystem expansion out of OS configuration
just a clean up.
2024-08-06 18:39:37 +02:00
OpenGnSys Support Team 9a52df7711 postinstall: add logging to report postconfiguration script invocation 2024-08-06 18:16:23 +02:00
OpenGnSys Support Team 16251d42d3 postinstall: typo in maximum win hostname error
s/nor/not
2024-08-06 17:30:19 +02:00
OpenGnSys Support Team fd64b84bcc postinstall: linux does not allow more than 64 bytes long hostnames
As per:

  $ getconf HOST_NAME_MAX
  64

truncate it to the maximum.
2024-08-06 17:29:57 +02:00
OpenGnSys Support Team e9ee1b1c9f ogclient: remove external reference 2024-08-06 10:56:30 +02:00
OpenGnSys Support Team 1011957bb7 live: use correct loglevel when reporting issues with listing cache contents
instead of using info to report errors.
2024-07-31 22:29:29 +02:00
OpenGnSys Support Team 9b317cf3e0 utils: disk: revisit logging to find EFI partition
instead of

	Checking partition "Microsoft Basic Data"...
	Checking partition "EFI System"...

show

	Searching EFI partition...
	EFI partition found at /dev/sda1

and refer to EFI partition consistently in logs.
2024-07-30 16:50:17 +02:00
OpenGnSys Support Team 9a553765b4 utils: postinstall: show hostname in logs
Display the hostname that is set in the logs.
2024-07-30 16:40:07 +02:00
OpenGnSys Support Team 1329c0955b live: validate checksum only once if image is already in cache
if image already exists in the cache, skip a second checksum validation.

log shows duplicated entries:

	Verifying checksum for example.img, please wait...
	Checksum is OK for example.img
	Verifying checksum for example.img, please wait...
	Checksum is OK for example.img

because tip_check_csum() is called twice in this case.
2024-07-30 16:19:03 +02:00
OpenGnSys Support Team 1376b1900d live: remove old image and checksum file on download
Restoring an updated image file (with different checksum) could fail while the
old checksum file could remain in place.

Remove image and checksum file before fetching the new files.
2024-07-30 16:11:43 +02:00
OpenGnSys Support Team 49017c00ca utils: tip_check_csum() uses local checksum file
.full.sum file in the local cache contains the local checksum for this file,
this checksum is calculated by tip_write_csum(), therefore, there is no need to
calculate this checksum again from the image file in the cache, use this
checksum content instead.

if .full.sum is not available, then cache is inconsistent, tip_check_csum()
is called after checking if image file exists, raise an exception.

checksum could mismatch in two situations:

a) new image version (checksum is different)
b) image is corrupted

in both cases, a new fresh image needs to be retrieved.

this speeds up checksum validation.
2024-07-30 16:11:40 +02:00
OpenGnSys Support Team a846d5e343 live: unicast-direct does not validate checksum
this restore method is unreliable, add warning to the logs.
2024-07-30 00:51:37 +02:00
OpenGnSys Support Team c6ab7a4a2d utils: enhance logging for checksum mismatch
display checksum for server and local file when checksum mismatches.
2024-07-30 00:51:37 +02:00
OpenGnSys Support Team 8395982244 live: validate file existence and checksum for unicast cache
after copying file to cache, validate that file exists in cache and checksum
correct.
2024-07-30 00:51:37 +02:00
Alejandro Sirgo Rica 210a70fc73 utils: add set_linux_hostname
Add set_linux_hostname function to redefine the hostname of a
Linux install by overwriting the contents of /etc/hostname
2024-07-29 15:07:22 +02:00
Alejandro Sirgo Rica adbf02d170 utils: add set_windows_hostname
Add function to redefine the hostname of a Windows install.
Windows hostnames can't be larger than 15 characters due to
legacy heritage.

Hostname modification is done by modifying 3 registry values in
the ControlSetXXX entry of the SYSTEM hive. ControlSet001 is
generally the entry to be edited but one must query the value
of the 'Current' key in the 'Select' entry of the SYSTEM hive
to retrieve the active ControlSet.

The hostname has to be introduced in the following entries:
path = 'ControlSetXX/Control/ComputerName/ComputerName'
key = 'ComputerName'

path = 'ControlSetXXX/Services/Tcpip/Parameters'
key = 'HostName'
key = 'NV Hostname'

The value to store in those keys is of tipe SZ and has to be
encoded in UCS-2 Little Endian (utf-16-le).
2024-07-29 15:07:22 +02:00
Alejandro Sirgo Rica 567fea276e utils: add postinstall.py
Replace ConfigureOs script by native calls to:

- update BCD via hivex using bcd.py and winreg.py infrastructure.
- restore efi bootloader restore_windows_efi_bootloader().

Call legacy scripts for remaining postinstall procedures to
replace them incrementally.

Define variable CONFIGUREOS_LEGACY_ENABLED as False by default.
Run legacy configureOs when CONFIGUREOS_LEGACY_ENABLED = True.
This serves as a auxiliar method to keep the restoration functional
in case of problems with the new configure_os logic.
2024-07-29 15:07:22 +02:00
Alejandro Sirgo Rica 9d5291f47a utils: add BCD native support
Implement update_bcd() as replacement of ogWindowsBootParameters.
The legacy function modified the BCD of a freshly restored system
invoking the privative binary "spartlnx".

The script edits a set of BCD entries needed for a proper system
boot.

Each main BCD entry is identified by an UUID and contain a set of
subnodes, these hold the configuration and entry information.
Each node contains data in the form of key-value.

Common BCD structure:

'Objects'
...

The Boot Manager entry is always identified by the UUID
9dea862c-5cdd-4e70-acc1-f32b344d4795.
Some entries always have the same UUID as identifier such the
Boot Manager while other have different UUID depending on the system.
To identify these entries with a not known UUID we query the value
'Type' of the node 'Description'. This contains a 32 bit value whose
bytes codify the nature of the entry.

We obtain 3 different values as a tuple, each value is the result of
applying a bitmask to the Type value. These masks are 0xf0000000,
0x00f00000 and 0x000fffff. The resulting tuple of 3 values is then
used to obtain the corresponding entry from a map.

The data we modify from the BCD are disk and partition references
to point to the new disk and partition in the system where the
images are restored. Partition and disk information is stored as
UUID in specific offsets inside binary data in the BCD.
To update these we need to obtain the disk and partition UUIDs,
then convert it to bytes as follows:

original UUID: C4C61C51-3456-4733-96AD-AE760A41C392
UUID as bytes: 51 1C C6 C4 56 34 33 47 96 AD AE 76 0A 41 C3 92

The modified entries are: Resume from Hibernation, Windows Boot
Loader OS, Windows Boot Loader Recovery, Windows Recovery,
Boot Loader Settings, Windows Boot Manager and Windows Memory
Diagnostic.
Some of these options could be omited as the system restoration
does not include a recovery partition so in this case all the
recovery related entries just point to the main system partition.

Most entries are edited modifying the value corresponding to the
key 'Element' in 2 subnodes of the 'Elements' node.
These subnodes are '11000001' and '21000001'.

'Objects'

The 2 values stored in these 2 entries is binary data where we
store the partition and disk bytes. We simply replace the byte
representation of out UUIDS in the binary data. Partition is
stored in offset 32 and the disk in offset 56.
The exception is the Bootloader Recovery entry, in which the
partition offset is 84 and the disk offset 108.

Note that the legacy function only does a proper BCD edit in UEFI
systems. The new implementation follows the same behavior with
the possibility of implementing BCD modification under MBR
partitions in the future.

Set the field 16000009 (RECOVERY_ENABLED) to the value x00 to
disable recovery in both Resume from Hibernation and Windows
Boot Loader OS entries in the BCD.

The system install does not include any recovery partition so
it makes no sense to have it enabled.

This commit is preparatory work for the new native postinstall code.
2024-07-29 15:07:22 +02:00
Alejandro Sirgo Rica bb03e92840 utils: add win edit registry utilities
Add winreg.py to the utils folder. Implement hive enum types,
hive handler validation and validated get_* functions for
nodes and registry values.

Implement the utility hive operations through the Hivex library.

This serves as preparatory work for BCD manipulation but it also
has potential to improve registry usage in previous code.

UCS-2 Little Endian is the prefered windows registry text encoding
for binary content. Define a WINDOWS_HIVE_ENCODING global variable
to use when encoding string to write in the win registry.

This commit is preparatory work for the new native postinstall code.
2024-07-29 15:07:22 +02:00
Alejandro Sirgo Rica 7ab965c0b5 utils: add restore_windows_efi_bootloader
Add restore_windows_efi_bootloader to copy the EFI loader from
the filesystem in the restored system into the EFI partition.

This commit is preparatory work for the new native postinstall code.
2024-07-29 15:07:22 +02:00
Alejandro Sirgo Rica 4f31bde549 utils: add functions to obtain disk and partition UUIDs
Add get_partition_id and get_disk_id to obtain the UUID of a disk
or partition as a string. These values are obtained invoking the
program blkid as a subprocess.

This commit is preparatory work for the new native postinstall code.
2024-07-29 15:07:22 +02:00
Alejandro Sirgo Rica 41b5f830c6 utils: consolidate code to find efi loader
Add find_windows_efi_loader and find_linux_efi_loader to reduce
code duplication and to centralize efi loader path modifications.
2024-07-29 15:07:22 +02:00
Alejandro Sirgo Rica e20cda122b utils: rename ogExtendFs to extend_filesystem
Use a more consistent name format for the ogExtendFs function.
2024-07-29 15:07:22 +02:00
OpenGnSys Support Team 2c10b4c92a utils: fs: error out if mkfs fails
If formatting fails, log shows:

	mkfs.ntfs reports return code 1 for /dev/sda2

but ogclient reports success to the ogserver.

Raise an exception so front-end gets an indication that formatting has failed.
2024-07-29 14:22:48 +02:00
OpenGnSys Support Team 59fa3bb120 live: improve logging for file removal from cache
Provide a bit more logging to make it easier to debug issues.
2024-07-21 22:14:07 +02:00
OpenGnSys Support Team fcfa5f9fbc live: add logging to indicate image file copy from samba
For consistency with tiptorrent download.
2024-07-21 21:59:27 +02:00
OpenGnSys Support Team 59ab9204ce utils: consolidate logging to write checksum file to cache
Move log message to function that is called both by unicast and tiptorrent.
2024-07-21 21:56:09 +02:00