Some older operating systems (e.g. RHEL6) use a non-default filename
on the root disk and rely on setting an EFI variable to point to the
bootloader. This does not work when performing a SAN boot on a
machine where the EFI variable is not present.
Fix by allowing a non-default filename to be specified via the
"sanboot --filename" option or the "san-filename" setting. For
example:
sanboot --filename \efi\redhat\grub.efi \
iscsi:192.168.0.1::::iqn.2010-04.org.ipxe.demo:rhel6
or
option ipxe.san-filename code 188 = string;
option ipxe.san-filename "\\efi\\redhat\\grub.efi";
option root-path "iscsi:192.168.0.1::::iqn.2010-04.org.ipxe.demo:rhel6";
Originally-implemented-by: Vishvananda Ishaya Abrams <vish.ishaya@oracle.com>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Add basic support for multipath block devices. The "sanboot" and
"sanhook" commands now accept a list of SAN URIs. We open all URIs
concurrently. The first connection to become available for issuing
block device commands is marked as the active path and used for all
subsequent commands; all other connections are then closed. Whenever
the active path fails, we reopen all URIs and repeat the process.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Allow the active timer (providing udelay() and currticks()) to be
selected at runtime based on probing during the INIT_EARLY stage of
initialisation.
TICKS_PER_SEC is now a fixed compile-time constant for all builds, and
is independent of the underlying clock tick rate. We choose the value
1024 to allow multiplications and divisions on seconds to be converted
to bit shifts.
TICKS_PER_MS is defined as 1, allowing multiplications and divisions
on milliseconds to be omitted entirely. The 2% inaccuracy in this
definition is negligible when using the standard BIOS timer (running
at around 18.2Hz).
TIMER_RDTSC now checks for a constant TSC before claiming to be a
usable timer. (This timer can be tested in KVM via the command-line
option "-cpu host,+invtsc".)
Signed-off-by: Michael Brown <mcb30@ipxe.org>
As of commit b1caa48 ("[crypto] Support SHA-{224,384,512} in X.509
certificates"), the list of supported cryptographic algorithms is
controlled by config/crypto.h.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Relicense files with kind permission from
Stefan Hajnoczi <stefanha@redhat.com>
alongside the contributors who have already granted such relicensing
permission.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
At some point in the past few years, binutils became more aggressive
at removing unused symbols. To function as a symbol requirement, a
relocation record must now be in a section marked with @progbits and
must not be in a section which gets discarded during the link (either
via --gc-sections or via /DISCARD/).
Update REQUIRE_SYMBOL() to generate relocation records meeting these
criteria. To minimise the impact upon the final binary size, we use
existing symbols (specified via the REQUIRING_SYMBOL() macro) as the
relocation targets where possible. We use R_386_NONE or R_X86_64_NONE
relocation types to prevent any actual unwanted relocation taking
place. Where no suitable symbol exists for REQUIRING_SYMBOL() (such
as in config.c), the macro PROVIDE_REQUIRING_SYMBOL() can be used to
generate a one-byte-long symbol to act as the relocation target.
If there are versions of binutils for which this approach fails, then
the fallback will probably involve killing off REQUEST_SYMBOL(),
redefining REQUIRE_SYMBOL() to use the current definition of
REQUEST_SYMBOL(), and postprocessing the linked ELF file with
something along the lines of "nm -u | wc -l" to check that there are
no undefined symbols remaining.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
These files cannot be automatically relicensed by util/relicense.pl
since they either contain unusual but trivial contributions (such as
the addition of __nonnull function attributes), or contain lines
dating back to the initial git revision (and so require manual
knowledge of the code's origin).
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Relicence files with kind permission from the following contributors:
Alex Williamson <alex.williamson@redhat.com>
Eduardo Habkost <ehabkost@redhat.com>
Greg Jednaszewski <jednaszewski@gmail.com>
H. Peter Anvin <hpa@zytor.com>
Marin Hannache <git@mareo.fr>
Robin Smidsrød <robin@smidsrod.no>
Shao Miller <sha0.miller@gmail.com>
Thomas Horsten <thomas@horsten.com>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Relicense files authored by Dan Lynch while working as an employee of
Fen Systems Ltd., with permission from Fen Systems Ltd.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Some of the C library string functions have an unknown provenance.
Reimplement all such functions to avoid potential licensing
uncertainty.
Remove the inline-assembler versions of strlen(), memswap(), and
strncmp(); these save a minimal amount of space (around 40 bytes in
total) and are not performance-critical.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Use PRODUCT_SHORT_NAME instead of a hardcoded "iPXE" for strings which
are typically shown in the user interface.
Note that this only allows for customisation of the user interface.
Where the "iPXE" string serves a technical purpose (such as in the
HTTP User-Agent), the string cannot be customised.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Add the "-c <count>" option to the "ping" command, allowing for
automatic termination after a specified number of packets.
When a number of packets is specified:
- if a serious error (i.e. length mismatch or content mismatch)
occurs, then the ping will be immediately terminated with the relevant
status code;
- if at least one response is received successfully, and all errors
are non-serious (i.e. timeouts or out-of-sequence responses), then
the ping will be terminated after the final response (or timeout)
with a success status;
- if no responses are received successfully, then the ping will be
terminated after the final timeout with ETIMEDOUT.
If no number of packets is specified, then the ping will continue
until manually interrupted.
Originally-implemented-by: Cedric Levasseur <cyr-ius@ipocus.net>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Inhibit implicit sign-padding of characters with the top bit set
(e.g. accented characters), which confuses the mucurses library by
colliding with the bits used to store character attributes and
colours.
Reported-by: Marc Delisle <Marc.Delisle@cegepsherbrooke.qc.ca>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
iPXE will detect timeout failures in several situations: network
link-up, DHCP, TCP connection attempts, unacknowledged TCP data, etc.
This does not cover all possible circumstances. For example, if a
connection to a web server is successfully established and the web
server acknowledges the HTTP request but never sends any data in
response, then no timeout will be triggered. There is no timeout
defined within the HTTP specifications, and the underlying TCP
connection will not generate a timeout since it has no way to know
that the HTTP layer is expecting to receive data from the server.
Add a "--timeout" parameter to "imgfetch", "chain", etc. If no
progress is made (i.e. no data is downloaded) within the timeout
period, then the download will be aborted.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Rename the "--bpp" option to "--depth", to free up the single-letter
option "-b" for "--bottom" in preparation for adding margin support.
This does not break backwards compatibility with documented features,
since the "console" command has not yet been documented.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Provide a mechanism for consoles to update the recorded console width
and height, and use this width and height to provide the curses COLS
and LINES variables.
We choose not to use ANSI escape sequences to obtain the width and
height, for two reasons:
- iPXE's model is that all output is sent to all consoles; we could
therefore end up with multiple consoles reporting conflicting widths
and heights
- when a serial console is in use, we probably don't want to resize
the output shown on the BIOS console to match the size of the serial
console, since it's likely that the serial console is in use only
for debugging.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Allow for multiple setting definitions with the same name but
different scopes and tags. For example, allow for a "filename"
setting with default scope and tag value 67 (for DHCPv4) and a
corresponding "filename" setting with IPv6 scope and tag value 59 (for
DHCPv6).
Signed-off-by: Michael Brown <mcb30@ipxe.org>
The fetch_setting() family of functions may currently modify the
definition of the specified setting (e.g. to add missing type
information). Clean up this interface by requiring callers to provide
an explicit buffer to contain the completed definition of the fetched
setting, if required.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Parsing a timeout value (specified in milliseconds) into an internal
timeout value measured in timer ticks is a common operation. Provide
a parse_timeout() value to carry out this conversion automatically.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
The "inc" command allows the numeric value of a setting to be
incremented, allowing for the construction of simple loops within an
iPXE script.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
A deliberate side effect of this commit is that the "read" command
will now preserve the type of the setting, if the setting name
contains no type information. For example:
iPXE> set foo:ipv4 192.168.0.1
iPXE> read foo
192.168.0.100
iPXE> show foo
foo:ipv4 = 192.168.0.100
rather than the arguably unexpected behaviour of resetting the type to
"string".
Signed-off-by: Michael Brown <mcb30@ipxe.org>
The getopt API defines optind as a global variable. When used by the
"autoboot" command, the payload function passed to ifcommon_exec() may
result in a new iPXE script being executed; the commands therein would
then overwrite the value of optind. On returning, ifcommon_exec()
would continue processing the list of interfaces from an undefined
point.
Fix by using a local variable to hold the index within the list of
interfaces.
Reported-by: Robin Smidsrød <robin@smidsrod.no>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Add support for page up, page down, home and end keys, matching the
navigation logic used in the menu user interface.
Originally-implemented-by: Marin Hannache <git@mareo.fr>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Add a facility for settings blocks to act as symbolic links to other
settings blocks, and reimplement the "netX" virtual settings block
using this facility.
The primary advantage of this approach is that unscoped settings such
as ${mac} and ${filename} will now reflect the settings obtained from
the most recently opened network device: in most cases, this will mean
the settings obtained from the most recent DHCP attempt. This should
improve conformance to the principle of least astonishment.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Abstract out the ability to reboot the system to a separate reboot()
function (with platform-specific implementations), add an EFI
implementation, and make the existing "reboot" command available under
EFI.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Nothing currently prevents a menu separator from being assigned a
shortcut key, and then from being selected using that shortcut key.
This produces an inconsistency in the user interface, since separators
cannot be selected by other means of menu navigation (arrow keys, page
up/down, etc).
It would be trivial to prevent separators from being assigned shortcut
keys, but this would eliminate one potentially useful use case: having
a large menu and using shortcut keys to jump to a section within the
menu.
Fix by treating a shortcut key on a separator as equivalent to "select
the separator, then press the down arrow key". This has the effect of
moving to the first non-separator menu item following the specified
separator, which is probably the most intuitive behaviour. (The
existing logic for moving the selection already handles the various
nasty corner cases such as a menu ending with one or more separators.)
Reported-by: Ján ONDREJ (SAL) <ondrejj@salstar.sk>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Unrecognised keys may be returned by getkey() as character code zero,
which currently matches against the first menu item with no shortcut
key defined.
Prevent this unintended behaviour by explicitly checking that the menu
item has a defined shortcut key.
Reported-by: Ján ONDREJ (SAL) <ondrejj@salstar.sk>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
When prompting the user to enter a setting value via the "read"
command, prefill the input buffer with the setting's current value.
Requested-by: Ján Ondrej (SAL) <ondrejj@salstar.ks>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
When fetching a named setting using a name that does not explicitly
specify a type, default to using the type stored when the setting was
created, rather than always defaulting to "string". This allows the
behaviour of user-defined settings to match the behaviour of
predefined settings (which have a sensible default type).
For example:
set server:ipv4 192.168.0.1
echo ${server}
will now print "192.168.0.1", rather than trying to print out the raw
IPv4 address bytes as a string.
The downside of this change is that existing tricks for printing
special characters within scripts may require (backwards-compatible)
modification. For example, the "clear screen" sequence:
set esc:hex 1b
set cls ${esc}[2J
echo ${cls}
will now have to become
set esc:hex 1b
set cls ${esc:string}[2J # Must now explicitly specify ":string"
echo ${cls}
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Expose image tail-recursion to iPXE scripts via the "--replace"
option. This functions similarly to exec() under Unix: the
currently-executing script is replaced with the new image (as opposed
to running the new image as a subroutine).
Signed-off-by: Michael Brown <mcb30@ipxe.org>
A reasonably large (512MB) file transferred via HTTP over Gigabit
Ethernet should complete in around 4.6 seconds. Increase the
resolution of the "time" command to tenths of a second, to allow such
transfers to be meaningfully measured.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
Add "sync" command (loosely based on the Unix "sync"), which will wait
for any pending operations to complete.
Signed-off-by: Michael Brown <mcb30@ipxe.org>
The "no" keymap is for a Dvorak keyboard.
Reported-by: Robin Smidsrød <robin@smidsrod.no>
Tested-by: Robin Smidsrød <robin@smidsrod.no>
Signed-off-by: Michael Brown <mcb30@ipxe.org>
The output from text-based user interfaces such as the "config"
command is not generally meaningful for logfile-based consoles such as
syslog and vmconsole.
Signed-off-by: Michael Brown <mcb30@ipxe.org>